Balanced Performance
- Low priming volume, high gas exchange and low pressure drop are optimally balanced for superb performance.
- Hollow fibers manufactured exclusively by Terumo using a patented technology with total quality management from raw materials to finished product.
- Woven fiber bundle ensures consistent and high-performance gas exchange.
- Choice of blood outlet port configurations for easy access and increased circuit flexibility.
- Top-to-bottom blood flow path and air purge line provide excellent air removal capability.
- No DEHP used in PVC tubing.
Hardshell Reservoir
Full Featured
- Elongated shape provides a stable blood flow path and enhanced visibility at all levels from all angles.
- Rotating venous inlet improves set-up flexibility.
- No DEHP used in PVC tubing.
- Connecting mount increases flexibility in circuit set-up and oxygenator rotation.
- Funnel-shaped cardiotomy filter improves breakthrough and residual volumes.
- Positive pressure relief value for additional safety.
Features
The design of the Capiox® RX Oxygenator
|
|
|
|
|
|

What is prescriptive oxygenator?
Prescriptive Oxygenation is Terumo’s unique approach to helping you meet each patient’s oxygenation and blood management needs more precisely, with the freedom to choose the right size CAPIOX oxygenator.What is clinical benefit of low prime volume oxygenator ?
Minimization of the oxygenator priming volume is associated with fewer RBC transfusion and reduce hemodilution in bypass surgery.Catalog Number | Description | Unit/Case |
---|---|---|
CAPIOX® RX05 Baby RX® Oxygenator | ||
1CX*RX05REA | Oxygenator, 0.5 m2 surface area, 0.1 - 1.5 LPM flow rate, with hardshell reservoir, with Xcoating™ surface coating Oxy inlet on left when outlet is facing away from user | 4 |
1CX*RX05RWA | Oxygenator, 0.5 m2 surface area, 0.1 - 1.5 LPM flow rate, with hardshell reservoir, with Xcoating™ surface coating Oxy inlet on right when outlet is facing away from user | 4 |
CAPIOX® RX15 Oxygenator | ||
1CX*RX15E | Oxygenator, 1.5 m2 surface area, 0.5 - 5.0 LPM flow rate, with integrated arterial filter and Xcoating™ surface coating Oxy inlet on left when outlet is facing away from user | 4 |
3CX*RX15RE30 | Oxygenator, 1.5 m2 surface area, 0.5 - 4.0 LPM flow rate, with 3000 mL hardshell reservoir with Xcoating™ surface coating Oxy inlet on left when outlet is facing away from user | 4 |
3CX*RX15RE40 | Oxygenator, 1.5 m2 surface area, 0.5 - 5.0 LPM flow rate, with 4000 mL hardshell reservoir with Xcoating™ surface coating Oxy inlet on left when outlet is facing away from user | 4 |
3CX*RX15RW30 | Oxygenator, 1.5 m2 surface area, 0.5 - 4.0 LPM flow rate, with 3000 mL hardshell reservoir with Xcoating™ surface coating Oxy inlet on right when outlet is facing away from user | 4 |
3CX*FX15RW30C | Oxygenator, 1.5 m2 surface area, 0.5 - 5.0 LPM flow rate, with 3000 mL hardshell reservoir, with integrated arterial filter and Xcoating™ surface coating Oxy inlet on right when outlet is facing away from user | 4 |
3CX*RX15RW40 | Oxygenator, 1.5 m2 surface area, 0.5 - 5.0 LPM flow rate, with 4000 mL hardshell reservoir with Xcoating™ surface coating Oxy inlet on right when outlet is facing away from user | 4 |
CAPIOX® RX25 Oxygenator | ||
3CX*RX25RE | Oxygenator, 2.5 m2 surface area, 0.5 - 7.0 LPM flow rate, with integrated hardshell reservoir, with Xcoating™ surface coating Oxy inlet on left when outlet is facing away from user | 4 |
3CX*RX25RW | Oxygenator, 2.5 m2 surface area, 0.5 - 7.0 LPM flow rate, with integrated hardshell reservoir, with Xcoating™ surface coating Oxy inlet on right when outlet is facing away from user | 4 |
Holders for Oxygenators | ||
801139 | Holder for RX/FX oxygenators with hardshell reservoir, short arm, gray | 1 |
801804 | Holder for RX/FX oxygenators with hardshell reservoir, long arm, gray | 1 |
1XX*CXH05 | Holder for RX05/FX05 oxygenators | 1 |
1XX*CXH05R | Holder for RX05/FX05 oxygenator with hardshell reservoir | 1 |
1XX*CXH05AD | Adapter for RX/FX holder for RX05/FX05 oxygenators | 1 |
1XX*CXH15 | Holder for RX15/RX25, FX15/FX25 oxygenators | 1 |
1XX*CXH18 | Holder for RX15/RX25, FX15/FX25 oxygenators when separated from reservoir | 1 |
1XX*CXH18R | Holder for CAPIOX oxygenators with hardshell reservoir, long angled arm | 1 |
1XX*CXH25F | Holder for RX15/RX25, FX15/FX25 Advance oxygenators when separated from reservoir | 1 |
Accessories for Oxygenation Systems | ||
1CX*TL | Luer design thermistor for CAPIOX® oxygenators [86] | 10 |
1CX*BP021 | Thermistor wire, blue | 10 |
1CX*BP022 | Thermistor wire, red | 10 |
Vacuum-Assisted Venous Drainage Kit | ||
62432 | Tubing kit Includes moisture trap and negative pressure relief valves | 5 |
Sampling Manifold | ||
60042 | 5-gang manifold | 10 |
63627 | Sampling manifold and lines | 5 |
1XX*XH051 | Holder for sampling manifold | 1 |