CDI® Blood Parameter Monitoring System 550


Real-time monitoring of DO2 as one of 12 blood parameters.
CONTACT a REPRESENTATIVE

The industry standard for continuous in-line blood parameter monitoring.

 

With the addition of in-line monitoring of oxygen delivery (DO2), CDI® Blood Parameter Monitoring System 550 provides the continuous information needed to reduce the risk of acute kidney injury, improve patient outcomes and save hospital costs.

Real-time monitoring of DO2, one of 12 key blood parameters, provides critical information required for goal directed perfusion, helping to achieve optimal perfusion during cardiopulmonary bypass surgery. User selectable limits provide alerts when values are approaching critical DO2 thresholds.

CDI System 550 offers a full range of next-generation features, including market-leading optical fluorescence technology, a high-visibility LCD screen, advanced probe design, IEC 60601-1 3rd Edition compliance, and more.

Proven technology and exceptional quality backed by Terumo’s dedicated support make the CDI System 550 the smart choice.

Features

CDI® System 550 Measures or Calculates 12 Critical Blood Parameters

 

The CDI Blood Parameter Monitoring System 550 (CDI System 550) was designed and developed to enable continuous monitoring of in-line blood parameters — pH, pCO2, PO2, K+, temperature, SO2, hematocrit, hemoglobin, base excess, bicarbonate, oxygen consumption and oxygen delivery during cardiopulmonary bypass (CPB). Using optical fluorescence and reflectance technologies and disposable sensors placed in the extracorporeal circuit, the CDI System 550 monitors and displays real-time changes in blood parameters.

 

  • Allow real-time response to change in blood parameters
  • System accuracy
  • Optical Fluorescence with Shunt Sensor
  • Optical Reflectance with H/S Cuvette
What is Oxygen Delivery?
Oxygen delivery is a critical indicator of perfusion, and is especially important when using Goal Directed Perfusion Therapy
What is Acute Kidney Injury?
AKI is defined as a rapid decline in renal filtration function. It is an episode of kidney failure or kidney damage, due to insufficient oxygen delivery, that happens within a few hours or a few days

Videos

Continues DO2 Monitoring and 12 Key Blood Parameters

  • pH
  • pCO2
  • pO2
  • Temp
  • HCO3
  • BE
  • SO2
  • HCT
  • Hgb
  • K+
  • DO2
  • VO2
  • Flow

CDI 550 provides Real-time monitoring of DO2

Monitoring Oxygen delivery (DO2) provides critical information required for goal directed perfusion, helping to achieve optimal perfusion during cardiopulmonary bypass surgery and lower post operative AKI.

Catalog Number Description Unit/Case
CDI® Monitor
550AHCT Monitor with one blood parameter module and one hematocrit/saturation probe 1
550AVHCT Monitor with two blood parameter modules and one hematocrit/saturation probe 1
Calibrator
540 Calibrator 1
Displayed Parameters System Operating Ranges System Display Ranges
PH 6.8 to 7.8 pH units 6.5 to 8.5 pH units
pCO2 10 to 80 mmHg (1.3 to 10.7 kPa) 10 to 200 mmHg (1.3 to 26.7 kPa)
pO2 20 to 500 mmHg (2.7 to 66.7 kPa) 10 to 700 mmHg (1.3 to 93.3 kPa)
K+ 3.0 to 8.0 mmol/L 1.0 to 9.9 mmol/L
Product Dimension
Product Specification Size Weight
Monitor 28 cm x 38 cm x 17 cm 7.9 kg